Sales Director-Sandee |
Sales-Asa |
Sales-Erin |
Service-Alice |
TEL: 86-18576681886 FAX: 86-755-29077178 Email: [email protected] [email protected] |
DEUTZ TCD2012-L4(138HP) Diesel Engine for Engineering Curie high school drivers ed sign up.
General of DEUTZ TCD2012-L4 Diesel Engine for Engineering | |
Engine Model | TCD2012-L4 |
Cylinder | 4 |
Bore*Stroke | 101*126mm [4.0*5.0in] |
Capacity | 4.04L [247 cu in] |
Compression Ratio | 1:18 |
Max Rated Speed | 2400rpm |
Mean Piston Speed | 10.1m/s [33 ft/sec] |
Technical Specification of DEUTZ TCD2012-L4 Diesel Engine for Engineering | |
Power Output to ISO 14396 | 103 Kw [138 hp] |
At Engine Speed | 2400rpm |
At Mean, Effective Pressure | 12.8bar [186psi] |
Max. Torque | 520N.m [384lb-ft] |
At Engine Speed | 1600rpm |
Minimum Idling Speed | 650rpm |
Specific Fuel Consumption | 215g/kW.h [0.35lb/hp-hr] |
Weight as per DIN 70020 Part 7A | 400Kg [882lb] |
Welcome to contact us for more information of DEUTZTCD2012-L4(138HP)Diesel Engine for Engineering
DEUTZ TCD Diesel engine [ TCD2012-L6(208HP)TCD2012-L6(252.1HP)TCD2013-L6-2VTCD2013-L6-4V(261KW)TCD2015-V08TCD2015-V8
Title | File Size | Download Link |
DEUTZ EMR3 – Diagnostic trouble codes DTC.pdf | 289.4kb | Download |
Deutz TCD 2015 V08 EMR3 Diagnostic trouble codes.pdf | 62.4kb | Download |
DEUTZ Trouble Code List EMR4.pdf | 996.4kb | Download |
Dtc List Deutz Engine.pdf | 359.9kb | Download |
EMS2 Deutz Fault Codes.pdf | 1.3Mb | Download |
Tabela de Falhas Motor Deutz.pdf | 556.3kb | Download |
Short (0.4 C) | Long (0.8 c) | Short (0.4 C) | Function / Component | Error |
---|---|---|---|---|
1 | 2 | 3 | Output к Lamps Temperature Cooling Liquid | Wrong signal, exceeding device temperature Management |
1 | 2 | 6 | Adjustment Number Revolutions Manually | Wrong / Incomprehensible Signal |
1 | 2 | 8 | Sensor Temperature Intake Air | Wrong Signal |
1 | 3 | 3 | Sensor Temperature Transmission Oil | Wrong Signal |
1 | 3 | 4 | Control Pressure System Rail | Incomprehensible signal, pressure/deflection of pressure Limits of permissible range |
1 | 3 | 5 | Output to the oil pressure signal lamp | Wrong signal, exceeding device temperature Management |
1 | 3 | 5 | Output To the valve of the dosing unit Fuel | Wrong signal, exceeding device temperature Management |
1 | 3 | 6 | Control Air Filter | The air pressure behind the filter is too low |
1 | 3 | 7 | Output To Executive Devices | Short Circuit On Battery |
1 | 3 | 8 | Output To Executive Devices | Short Circuit On Housing |
1 | 4 | 2 | Output to the engine work lamp | Wrong signal, exceeding device temperature Management |
1 | 4 | 3 | Multi Switch 1 / 2 / 3 | Wrong / Incomprehensible Signal |
1 | 4 | 4 | Sensor Temperature Lube Oil | Wrong / Incomprehensible Signal |
1 | 4 | 4 | Control Temperature Oil | Temperature Out Specified Range |
1 | 4 | 5 | Control Switch Lock Automation | Incomprehensible Signal |
1 | 4 | 6 | Reducing Valve System Rail | Valve Opened / Need Push Pressure / After Push Pressure Not Open |
1 | 4 | 7 | Sensor Pressure System Rail | Incorrect signal, deviation of pressure outside Valid range |
2 | 3 | 1 | Control Pressure Oil | Pressure Out Specified Range |
2 | 3 | 2 | Control Temperature Cooling Liquid | Temperature Above Specified Range |
2 | 3 | 3 | Control Temperature Intake Air | Temperature Above Specified Range |
2 | 3 | 5 | Control Level Cooling Liquid | Level Below Specified Range |
2 | 3 | 7 | Control Temperature Fuel | Temperature Out Specified Range |
2 | 3 | 8 | Output To Executive Device Fan 1/2 | Wrong signal, exceeding device temperature Management |
2 | 3 | 8 | Control Number Revolutions Fan | Number of revolutions outside the specified range |
2 | 4 | 1 | Control Combustion | Ignition interruptions detected in one or more Cylinders |
2 | 6 | 1 | Exit control To Executive Devices | Relay Not Open Or Open с Late Short Closure on Housing |
2 | 6 | 3 | Output To A device that facilitates Cold start | Incorrect signal, malfunction of the relay, seizes or Incorrectly connected, short circuit |
2 | 7 | 1 | Bus CAN | One or more data block timeouts, Bus inactive |
2 | 8 | 2 | Voltage Power Sensor 1 / 2 / 3 | Voltage outside the specified range |
2 | 9 | 2 | Sensor Atmospheric Pressure | Wrong / Incomprehensible Signal |
3 | 1 | 4 | Temperature sensor Oil For Hydraulic system | Wrong Signal |
3 | 1 | 4 | Temperature control Oil For Hydraulic system | Temperature Out Specified Range |
3 | 1 | 8 | Control Battery | Voltage Out Specified Range |
3 | 2 | 8 | Output to the control lamp of the device, Facilitating cold start | Wrong signal, exceeding device temperature Management |
4 | 1 | 4 | Exit to the external executive Device AGR | Wrong Signal |
4 | 1 | 5 | Exit to the external executive Device AGR | Wrong signal, exceeding device temperature Management |
4 | 1 | 6 | Exit to the external executive Device AGR | Wrong Signal |
4 | 1 | 7 | Chronometer Export Lube Oil | Reached Critical Just a moment |
5 | 1 | 2 | Output To Gauges Relay | Wrong signal, exceeding device temperature Management |
5 | 1 | 3 | Exit to the bulb-error indicator | Wrong signal, exceeding device temperature Management |
5 | 1 | 4 | Control Terminal 15 | Not Detected Signal |
5 | 1 | 5 | Control Terminal 50 | Detected Permanent Signal |
5 | 2 | 1 | Measurement Speed | Speed Movement Incomprehensible |
5 | 2 | 8 | Exit to internal motor brake | Wrong Signal |